Raised floor
A raised floor (access floor, raised access floor or platform floor) is a floor created above a solid floor slab, leaving an open void between the two. This void can be used to distribute building services, such as:
- Cabling for data and telecoms.
- Electrical power.
- Water supply and drainage.
- Heating, ventilation and air conditioning (HVAC).
- Cabling for environmental controls, fire detection and suppression and security.
Raised floors first emerged in the 1960’s and have become more common with the increasing demand for technology in buildings. They are often found in offices, or in spaces that have a high demand for information and communications infrastructure such as data centres.
The raised floor system allows flexibility of layout for building services and, with the inclusion of removable floor panels, allows quick and easy access for reconfiguration and maintenance. It also allow spaces to be reconfigured or refurbished with minimal disruption by the repositioning floor boxes, furniture or partition walls.
Typically, the components of raised flooring include:
- Pedestals, providing an adjustable vertical support structure for the raised floor. These may be bonded to the sub floor and adjusted to provide a level plane.
- Stringer bars, which can be used to join the pedestals together creating a framework for floor panels and giving lateral stability, particularly for deep floor void constructions.
- Floor panels, creating the flat surface of the raised floor.
- Floor finish, often carpet tiles which can be lifted to give access to the floor void.
- Floor boxes cut into floor panels, allowing services to penetrate through the floor and providing connection points for power, data, telecoms and so on.
Raised floors can be gravity or loose-lay systems in which the floor panels rest loose on the pedestal head, providing easy access to the floor voids below, or lock-down or screw-down raised floors in which the floor panels are fixed onto the pedestal head for greater security.
Typically, floor panels are 600mm x 600mm. They may be formed of a chipboard core, encased with steel, or may be laminated with finishes such as wood or stone. Floor voids can be as little as 20mm deep, and commonly, up to 1,200mm, although greater depths can be achieved by bespoke systems.
For many years, the Property Services Agency Specification MOB PF2 PS/Spu, Platform Floors (Raised Access Floors) Performance Specification, set the standards for raised floors, the last edition of which was published in 1992. This graded raised floors in four structural categories: light, medium, heavy and extra heavy.
However, this was superseded in 2001 by BSEN 12825:2001 Raised access floors, which classifies floor systems according to ultimate load, safety factor, deflection under working load and dimensional tolerances.
Raised floors can create a flanking route for sound to transmit from one space to another under partition walls. Floor finishes and panels with an acoustic construction can be used to reduce the transmission of sound, and the joints between panels can be minimised or sealed.
Acoustic insulation can also be introduced below partition walls, or walls can run through the raised floor to the floor slab, although this will reduce future flexibility. Generally, flanking is more likely through ceiling voids as ceiling tiles tend to have less mass than floor panels.
Where floor voids are used as plenums (that is they are used as ducts through which air can be supplied to or extracted from a space to provide ventilation) it may be necessary to specify a tight fit between floor panels or to seal joints between floor panels to prevent pressure loss.
[edit] Related articles on Designing Buildings Wiki
- Acoustic insulation.
- Decking.
- Ductwork.
- Finished floor level.
- Flanking sound.
- Floating floor.
- Floor definition.
- Flooring.
- Flooring defects.
- Herringbone strut.
- Joist.
- Metal furring system.
- Plenum.
- Rubber flooring.
- Separating floor.
- Sprung floor.
- Suspended ceiling.
- Types of floor.
- Underfloor air distribution.
Featured articles and news
HSE simplified advice for installers of stone worktops
After company fined for repeatedly failing to protect workers.
Co-located with 10th year of UK Construction Week.
How orchards can influence planning and development.
Time for knapping, no time for napping
Decorative split stone square patterns in facades.
A practical guide to the use of flint in design and architecture.
Designing for neurodiversity: driving change for the better
Accessible inclusive design translated into reality.
RIBA detailed response to Grenfell Inquiry Phase 2 report
Briefing notes following its initial 4 September response.
Approved Document B: Fire Safety from March
Current and future changes with historical documentation.
A New Year, a new look for BSRIA
As phase 1 of the BSRIA Living Laboratory is completed.
A must-attend event for the architecture industry.
Caroline Gumble to step down as CIOB CEO in 2025
After transformative tenure take on a leadership role within the engineering sector.
RIDDOR and the provisional statistics for 2023 / 2024
Work related deaths; over 50 percent from construction and 50 percent recorded as fall from height.
Solar PV company fined for health and safety failure
Work at height not properly planned and failure to take suitable steps to prevent a fall.
The term value when assessing the viability of developments
Consultation on the compulsory purchase process, compensation reforms and potential removal of hope value.
Trees are part of the history of how places have developed.
Comments